This explosion-proof heater is suitable for zone 1 and 2. The TEH 75 Ex features a multi-bladed non-sparking aluminum fan and has a heating capacity of 10kW. Due to its powerful and reliable performance and robust skid frame, this heater is ideally suited for industrial applications, for example.
- ATEX code Ex II 2 G d IIB T4 Gb
- Suitable for zone 1 and 2
- Ambient conditions -40 °C to +40 °C
- Heating capacity 10 kW
- Protection class IP55
- Voltage 3x400V + PE (50Hz)
- Free air delivery 1359 m³ / h
- Air speed 9,1 m / s
- Motor fan 1500 rpm
- Fan Multi-blade non-sparking aluminum
- Pressure protection Pressure relief valve
- Max. temperature rise 21,6°C
- Dimensions L x W x H 700 x 600 x 670 mm
- Plug: 400V / 32A
- Brand: CEAG
- ATEX code: Ex II 2 G the IIC T6